Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Biomech ; 40(2): 129-137, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237574

RESUMO

As markerless motion capture is increasingly used to measure 3-dimensional human pose, it is important to understand how markerless results can be interpreted alongside historical marker-based data and how they are impacted by clothing. We compared concurrent running kinematics and kinetics between marker-based and markerless motion capture, and between 2 markerless clothing conditions. Thirty adults ran on an instrumented treadmill wearing motion capture clothing while concurrent marker-based and markerless data were recorded, and ran a second time wearing athletic clothing (shorts and t-shirt) while markerless data were recorded. Differences calculated between the concurrent signals from both systems, and also between each participant's mean signals from both asynchronous clothing conditions were summarized across all participants using root mean square differences. Most kinematic and kinetic signals were visually consistent between systems and markerless clothing conditions. Between systems, joint center positions differed by 3 cm or less, sagittal plane joint angles differed by 5° or less, and frontal and transverse plane angles differed by 5° to 10°. Joint moments differed by 0.3 N·m/kg or less between systems. Differences were sensitive to segment coordinate system definitions, highlighting the effects of these definitions when comparing against historical data or other motion capture modalities.


Assuntos
Captura de Movimento , Corrida , Adulto , Humanos , Fenômenos Biomecânicos , Articulação do Joelho , Vestuário , Movimento (Física)
2.
J Biomech ; 141: 111182, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35749889

RESUMO

Markerless motion capture allows whole-body movements to be captured without the need for physical markers to be placed on the body. This enables motion capture analyses to be conducted in more ecologically valid environments. However, the influences of varied clothing on video-based markerless motion capture assessments remain largely unexplored. This study investigated two types of clothing conditions, "Sport" (gym shirt and shorts) and "Street" (unrestricted casual clothing), on gait parameters during overground walking by 29 participants at self-selected speeds using markerless motion capture. Segment lengths, gait spatiotemporal parameters, and lower-limb kinematics were compared between the two clothing conditions. Mean differences in segment length for the forearm, upper arm, thigh, and shank between clothing conditions ranged from 0.2 cm for the forearm to 0.9 cm for the thigh (p < 0.05 for thigh and shank) but below typical marker placement errors (1 - 2 cm). Seven out of 9 gait spatiotemporal parameters demonstrated statistically significant differences between clothing conditions (p < 0.05), however, these differences were approximately ten times smaller than minimal detectable changes in movement-related pathologies including multiple sclerosis and cerebral palsy. Hip, knee, and ankle joint angle root-mean-square deviation values averaged 2.6° and were comparable to previously reported average inter-session variability for this markerless system (2.8°). The results indicate that clothing, a potential limiting factor in markerless motion capture performance, would negligibly alter meaningful clinical interpretations under the conditions investigated.


Assuntos
Marcha , Caminhada , Fenômenos Biomecânicos , Vestuário , Humanos , Movimento (Física)
3.
J Biomech ; 127: 110665, 2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34380101

RESUMO

Kinematic analysis is a useful and widespread tool used in research and clinical biomechanics for the quantification of human movement. Common marker-based optical motion capture systems are time intensive and require highly trained operators to obtain kinematic data. Markerless motion capture systems offer an alternative method for the measurement of kinematic data with several practical benefits. This work compared the kinematics of human gait measured using a deep learning algorithm-based markerless motion capture system to those from a standard marker-based motion capture system. Thirty healthy adult participants walked on a treadmill while data were simultaneously recorded using eight video cameras and seven infrared optical motion capture cameras, providing synchronized markerless and marker-based data for comparison. The average root mean square distance (RMSD) between corresponding joint centers was less than 2.5 cm for all joints except the hip, which was 3.6 cm. Lower limb segment angles relative to the global coordinate system indicated the global segment pose estimates from both systems were very similar, with RMSD of less than 5.5° for all segment angles except those that represent rotations about the long axis of the segment. Lower limb joint angles captured similar patterns for flexion/extension at all joints, ab/adduction at the knee and hip, and toe-in/toe-out at the ankle. These findings indicate that the markerless system would be a suitable alternative technology in cases where the practical benefits of markerless data collection are preferred.


Assuntos
Marcha , Caminhada , Adulto , Articulação do Tornozelo , Fenômenos Biomecânicos , Humanos , Movimento (Física)
4.
J Biomech ; 122: 110414, 2021 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-33915475

RESUMO

Spatiotemporal parameters can characterize the gait patterns of individuals, allowing assessment of their health status and detection of clinically meaningful changes in their gait. Video-based markerless motion capture is a user-friendly, inexpensive, and widely applicable technology that could reduce the barriers to measuring spatiotemporal gait parameters in clinical and more diverse settings. Two studies were performed to determine whether gait parameters measured using markerless motion capture demonstrate concurrent validity with those measured using marker-based motion capture and a pressure-sensitive gait mat. For the first study, thirty healthy young adults performed treadmill gait at self-selected speeds while marker-based motion capture and synchronized video data were recorded simultaneously. For the second study, twenty-five healthy young adults performed over-ground gait at self-selected speeds while footfalls were recorded using a gait mat and synchronized video data were recorded simultaneously. Kinematic heel-strike and toe-off gait events were used to identify the same gait cycles between systems. Nine spatiotemporal gait parameters were measured by each system and directly compared between systems. Measurements were compared using Bland-Altman methods, mean differences, Pearson correlation coefficients, and intraclass correlation coefficients. The results indicate that markerless measurements of spatiotemporal gait parameters have good to excellent agreement with marker-based motion capture and gait mat systems, except for stance time and double limb support time relative to both systems and stride width relative to the gait mat. These findings indicate that markerless motion capture can adequately measure spatiotemporal gait parameters of healthy young adults during treadmill and over-ground gait.


Assuntos
Aprendizado Profundo , Algoritmos , Fenômenos Biomecânicos , Marcha , Humanos , Reprodutibilidade dos Testes , Caminhada , Adulto Jovem
5.
J Biomech ; 121: 110422, 2021 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-33873117

RESUMO

The clinical uptake and influence of gait analysis has been hindered by inherent limitations of marker-based motion capture systems, which have long been the standard method for the collection of gait data including kinematics. Markerless motion capture offers an alternative method for the collection of gait kinematics that presents several practical benefits over marker-based systems. This work aimed to determine the reliability of lower limb gait kinematics from video based markerless motion capture using an established experimental protocol for testing reliability. Eight healthy adult participants performed three sessions of five over-ground walking trials in their own self-selected clothing, separated by an average of 8.5 days, while eight synchronized and calibrated cameras recorded video. Three-dimensional pose estimates from the video data were used to compute lower limb joint angles. Inter-session variability, inter-trial variability, and the variability ratio were used to assess the reliability of the gait kinematics. Compared to repeatability studies based on marker-based motion capture, inter-trial variability was slightly greater than previously reported for some angles, with an average across all joint angles of 2.5°. Inter-session variability was smaller on average than all previously reported values, with an average across all joint angles of 2.8°. Variability ratios were all smaller than those previously reported with an average of 1.1, indicating that the multi-session protocol increased the total variability of joint angles by 10% of the inter-trial variability. These results indicate that gait kinematics can be reliably measured using markerless motion capture.


Assuntos
Marcha , Caminhada , Adulto , Fenômenos Biomecânicos , Humanos , Movimento (Física) , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...